SMC40 – Sensor Module Cabinet-Mounted from Siemens
Connection of purely serial encoders with EnDat22 interface to DRIVE-CLiQ
Encoder requirements
The sensor module cabinet-mounted SMC40 make it possible to connect encoders with the ordering designation EnDat22 to the DRIVE-CLiQ interface. The following encoder series are supported:
- Absolute linear encoders, such as: – LMBA – Linear Measuring Scale with LMKA – Encoder Head
- Absolute angle encoders, such as: – WMFA / WMRA – Measuring Flange with Ring Scale or Ring Scale with WMKA – Encoder Head
After switch-on, the SMC tests various characteristics of the connected encoder and automatically adapts itself to it. If the encoder does not fulfill the specific requirements, an error message is transmitted over the DRIVE-CLiQ interface.
DRIVE-CLiQ is a registered trademark of Siemens Aktiengesellschaft