Our product range of angle measuring systems WMK 2005 / WMK 2010 and WMK 2030 and our length measuring systems LMK 2005 / LMK 2010 and LMK 2030 can also be manufactured in an Ex-version.
They are therefore suitable for use in hazardous areas.
This is confirmed by the ATEX certificate II 2 G EX mb IIC T4 Gb
Breakdown:
II
equipment Group 2 (hazardous areas except mining)
2
category 2 (high level of security)
G
atmosphere: G = Gas
EX
explosion protection
mb
encapsulation, protection “mb”
IIC
explosion group (hazard: high, demand of resources: high)
T4
temperature class
(Maximum surface temperature of the equipment: 135 ° C.
Ignition temperature of flammable substances > 135 ° C)
Gb
Applicable equipment protection level
Our ex-systems may be used in zone 1 and 2!